Prerequisites
Place the vehicle on a flat surface with the wheels straight.
Connect the Vci to the vehicle.
Turn off the vehicle lights, close the doors.
No passengers on board and no cargo.
Tyre pressure in accordance with the manufacturer's specifications.
Fill all tanks (fuel, coolant, lubricant).
The spare wheel, jack and tools must be in place.
For vehicles with air suspension, the jack mode must be activated, or depending on the system, start the engine, wait until the suspension is level, turn the engine off and leave the ignition on.
The work area must be adequately lit.
Make sure there is no bright light or objects in the work area that could prevent calibration.
Check that the element to be calibrated is clean, in good condition and correctly fixed.
Depending on the vehicle, the element to be calibrated must be accessible (grille, cover, bumper, etc. to be removed).
01
02
03
04
- A if Radar calibration.
- B if camera calibration.
05
06
07
- Pointing the lasers at the rulers.
- Use the adjustment screw on the gantry to obtain an identical value for G and D.
08
- Position the plates on the mirror side claws.
- Point the lasers into the mirror.
- Use the gantry adjustment screw to obtain an identical value for G and D on the gantry scale.
09
- Set up the corresponding target.
- Centre the target on 0.
- Refer to the documentation to set the target height.
- The height scale on the gantry indicates the ash of the target.
- If you are using the latter, lower the slider to the floor and adjust it.
- Point the laser of the radar reflector at the centre of the radar.
10
You have
?